AH Bitumen Grades Heavy Traffic Specifications

AH-50

SPECIFICATION UNIT VALUE TEST METHOD
Penetration 1/10 Millimeters (mm 40-50 ASTM D5
Softening Point Degree Celsius (°C) 48-56 ASTM D36
Density, 25°C Kilogram per Cubic Meter (kg/m³) 1.000/1.060 ASTM D71/D3289
Ductility, 25°C Centimeters per Second (cm/s) 100 min ASTM D113
Loss On Heating Weight Percentage (WT%) 0.2 Max ASTM D6
Drop-in Penetration After Heating Percentage (%) 20 max ASTM D6/D5
Flash Point (Cleveland Open Cup) Degree Celsius (°C) 250 min ASTM D92
Solubility in Trichloroethylene Weight Percentage (WT%) 99.5 min ASTM D4
Spot Test Negative (−) or Positive (+) Negative AASHOT 102 *
Bitumen Content Percentage (%) 99.9 min ASTM D4
APPLICATION TEMPERATURE
APPLICATION UNIT RECOMMENDED TEMPERATURE
Storing Temperature Degree Celsius (°C) 120-150
Mixing Temperature Degree Celsius (°C) 135-155
Compacting Temperature Degree Celsius (°C) 125-145

AH-70

SPECIFICATION UNIT VALUE TEST METHOD
Penetration 1/10 Millimeters (mm) 60-70 ASTM D5
Softening Point Degree Celsius (°C) 48-56 ASTM D36
Density, 25°C Kilogram per Cubic Meter (kg/m³) 1.000/1.060 ASTM D71/D328
Ductility, 25°C Centimeters per Second (cm/s) 100 min ASTM D113
Loss On Heating Weight Percentage (WT%) 0.2 Max ASTM D6
Drop-in Penetration After Heating Percentage (%) 20 max ASTM D6/D5
Flash Point (Cleveland Open Cup) Flash Point (Cleveland Open Cup) 250 min ASTM D92
Solubility in Trichloroethylene Weight Percentage (WT%) 99.5 min ASTM D4
Spot Test Negative (−) or Positive (+) Negative AASHOT 102 *
Bitumen Content Percentage (%) 99.9 min ASTM D4
APPLICATION TEMPERATURE
APPLICATION UNIT RECOMMENDED TEMPERATURE
Storing Temperature Degree Celsius (°C) 120-150
Mixing Temperature Degree Celsius (°C) 135-155
Compacting Temperature Degree Celsius (°C) 125-145

AH-90

SPECIFICATION UNIT VALUE TEST METHOD
Penetration, 25°C 1/10 Millimeters (mm) 80-100 ASTM D5
Softening Point Degree Celsius (°C) 42-52 ASTM D36
Density, 25°C Kilogram per Cubic Meter (kg/m³) 1.000 min ASTM D71/D3289
Ductility, 25°C Centimeters per Second (cm/s) 100 min ASTM D113
Loss On Heating Weight Percentage (WT%) 0.5 Max ASTM D6
Drop-in Penetration After Heating Percentage (%) 20 Max ASTM D6805
Flash Point (Cleveland Open Cup) Degree Celsius (°C) 225 min ASTM D92
Solubility in Trichloroethylene Weight Percentage (WT%) 99 min ASTM D2042
Loss of Weight Percentage (%) 0.8 max ASTM D1754
Retained Penetration After Thin Film Percentage (%) 50 min ASTM D5
Ductility 25°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Ductility 15°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Temperature Degree Celsius (°C) Max 90-110 above the Soft
Bitumen Content Percentage (%) 99.9 min ASTM D4
APPLICATION TEMPERATURE
APPLICATION UNIT RECOMMENDED TEMPERATURE
Storing Temperature Degree Celsius (°C) 120-150
Mixing Temperature Degree Celsius (°C) 130-150
Compacting Temperature Degree Celsius (°C) 120-140

AH-110

SPECIFICATION UNIT VALUE TEST METHOD
Penetration, 25°C 1/10 Millimeters (mm) 80-110 ASTM D5
Softening Point Degree Celsius (°C) 45-52 ASTM D36
Density, 25°C Kilogram per Cubic Meter (kg/m³) 1.000 min ASTM D71/D3289
Ductility, 25°C Centimeters per Second (cm/s) 100 min ASTM D113
Loss On Heating Weight Percentage (WT%) 0.5 Max ASTM D6
Drop-in Penetration After Heating Percentage (%) 20 Max ASTM D6805
Flash Point (Cleveland Open Cup) Degree Celsius (°C) 225 min ASTM D92
Solubility in Trichloroethylene Weight Percentage (WT%) 99 min ASTM D2042
Loss of Weight Percentage (%) 0.8 max ASTM D1754
Retained Penetration After Thin Film Percentage (%) 50 min ASTM D5
Ductility 25°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Ductility 15°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Temperature Degree Celsius (°C) Max 90-110 above the Soft
Bitumen Content Percentage (%) 99.9 min ASTM D4
APPLICATION TEMPERATURE
APPLICATION UNIT RECOMMENDED TEMPERATURE
Storing Temperature Degree Celsius (°C) 120-150
Mixing Temperature Degree Celsius (°C) 130-150
Compacting Temperature Degree Celsius (°C) 120-140

AH-130

PROPERTY UNIT SPEC. METHOD
Penetration, 25°C 1/10 Millimeters (mm) 80-130 ASTM D5
Softening Point Degree Celsius (°C) 45-52 ASTM D36
Density, 25°C Kilogram per Cubic Meter (kg/m³) 1.000 min ASTM D71/D3289
Ductility, 25°C Centimeters per Second (cm/s) 100 min ASTM D113
Loss On Heating Weight Percentage (WT%) 0.5 Max ASTM D6
Drop-in Penetration After Heating Percentage (%) 20 Max ASTM D6805
Flash Point (Cleveland Open Cup) Degree Celsius (°C) 225 min ASTM D92
Solubility in Trichloroethylene Weight Percentage (WT%) 99 min ASTM D2042
Loss of Weight Percentage (%) 0.8 max ASTM D1754
Retained Penetration After Thin Film Percentage (%) 50 min ASTM D5
Ductility 25°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Ductility 15°C After Thin Film Oven Centimeters per Second (cm/s) 100 min ASTM D113
Temperature Degree Celsius (°C) Max 90-110 above the Soft
Bitumen Content Percentage (%) 99.9 min ASTM D4
APPLICATION TEMPERATURE
APPLICATION UNIT RECOMMENDED TEMPERATURE
Storing Temperature Degree Celsius (°C) 120-150
Mixing Temperature Degree Celsius (°C) 130-150
Compacting Temperature Degree Celsius (°C) 120-140